PowerTilt Tilting Coupler
PowerTilt Series Service & Repair Manual
HY34-1410
41
Parker Hannifin Corporation
Helac/Cylinder Division
Enumclaw, Washington USA
www.parker.com/helac
1. Clean all machined components thoroughly
in a wash tank and dry with compressed air.
2. Carefully inspect all critical areas: Seal
grooves, wear guide grooves, thrust
surfaces, shaft surfaces, housing bore and
gear teeth for any wear, corrosion and any
other signs of damage.
3. Locate the timing marks on the shaft (02),
piston sleeve assembly (03) and housing
ring gear (1.4). Re-mark with a permanent
marker or paint stick if needed.