6. Now make an alignment mark between the
lock ring (05) and shaft (02) splines. Then
remove the lock ring.
End Cap Torque Specifications
1. Reinstall the cross port relief valve (413) with
new O-rings and back up rings and torque to
60 Nm.
2. Coat the shaft port plug (101) threads with
Loctite 242 and install into the end of the
shaft (02) and torque to 305 Nm.
Model Torque (Nm) Hydraulic Pressure (bar)
4.5 135–150 35–40
06 475–680 35–40
07 750–910 35–40
08 1360–1630 40–45
09 1770–2175 35–40
10 2210–2650 35–40
11 2780–3330 35–40
12 3500–4200 35–40
Assembly
End Cap and Lock Ring Installation
Cross Port Relief Valve Installation