1. Begin with removing the port fittings and
plugs (124) to drain the hydraulic oil into a
suitable container.
2. When removing the standard pin-on coupler
or torque foot (6.1) and idler foot (6.2),
remove the shaft mounting screws (104).
4. Unthread and remove the lock ring screws
(120).
3. Secure the coupler using a hoist or
similar device.
Make sure the PowerTilt is thoroughly cleaned
prior to disassembly. Continue to clean all
machined parts in a wash tank and dry with
compressed air. Inspect the PowerTilt for
corrosion prior to disassembly.
Severe corrosion can make it dicult to remove
the lock ring screws (120) or set screws (129)
and unthread the end cap (04). If corrosion is
evident, soak the screws with penetrating oil for
several hours before disassembly.