DIP Switch Functions
Configure the OEM750/OEM750X’s DIP switches for your
motor and application. See Quick Test for switch location. The
following table and descriptions summarize switch settings.
on
off
3
off
45
7
6
1
8
2
Anti-resonance
Automatic Test
Current Loop Gain
Current Range
Anti-res. Disabled
Anti-res. Enabled
on
on offon on
off onon on
off offon on
on onon off
on offon off
on onon on
off onon off
off offon off
on onoff on
on offoff on
off onoff on
off offoff on
on onoff off
on offoff off
off onoff off
off offoff off
1
23
on
1
2
3
4
5
6
7
8
OEM750 DIP SETTINGS
Automatic Test Disabled
Automatic Test Enabled
Waveform
on
on
off
off
on
off
on
off
Automatic Standby
Full Current
75% Current
50% Current
25% Current
Default Setting
Default Setting
on
off
off
on
off
on
on
off
off
on
off
on
off
on
off
on
off
off
off
off
on
on
on
on
Pure Sine
-2% 3rd Harmonic
-4% 3rd Harmonic
-4% 3rd Harmonic
-4% 3rd Harmonic
-6% 3rd Harmonic
-8% 3rd Harmonic
-10% 3rd Harmonic
50,800
50,000
36,000
25,600
25,400
25,000
21,600
20,000
18,000
12,800
10,000
5,000
2,000
1,000
400
200
Default Setting
Default Setting
Default
5
46
7
8
off
off
off
off
on
on
on
on
off
off
on
on
off
off
on
on
off
on
off
on
off
on
off
on
1
2
4
8
16
32
64
64
SW 2
SW 3
1
2
3
4
5
6
7
8
O
N
O
N
Resolution
(Steps per Revolution)
off
off
on
on
off
on
off
on
2.5 – 7.5 amps
0.83 – 2.5 amps
0.7 – 2.0 amps
0.2 – 0.7 amps
Default Setting
Factory Default Con-
figuration Shown
Default Setting

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker OEM750 and is the answer not in the manual?

Parker OEM750 Specifications

General IconGeneral
BrandParker
ModelOEM750
CategoryServo Drives
LanguageEnglish

Related product manuals