10.2.3 Size
Size is in mm (in).
10.2.4 Connection to the Personal Computer
Operate as follows:
1. Plug in an end of the TTL cable into the TTL port of the serial interface.
2. Plug in the other end of the TTL cable into the programming port of the device.
3. Plug in and end of the USB cable into the USB port of the serial interface.
4. Plug in the other end of the USB cable into an USB port of the Personal Computer.
For further information consult the User manual if Parameters Manager.
10.3 Non optoisolated RS-485/USB serial interface
PSIF20SUXI
10.3.1 Introduction
PSIF20SUXI is a non optoisolated RS-485/USB serial interface.
Through the interface it is possible to connect the driver to the set-up software system Parameters Manager (using the
RS-485 port).
The interface is made of:
- RS-485 / USB non optoisolated serial interface
- USB cable (to connect the serial interface to the Personal Computer)
- RS-485 cable (this cable is not necessary because the connection serial interface-driver uses a three wires
connection).