EasyManua.ls Logo

PARMA-TECHNIK MIKRON III A - 11.10 Defect: Ignition; 11.11 Defect: Electrical Accessories

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
--------------------------------------------------------------
30
..
MIKRON
III
A
TROUBLESHOOTING
11.10.
Defect:
Ignition
Cause
of
Defect
a -
Spark
plugs
defective
b -
Improper
connection
of
the
ignition
cables
to
the
spark
plugs
c -
Magneto
distributor
cap
defect
d -
Breaker
contact
damage,
improper
contact
gap
or
dirt
e -
Magneto
grounding
circuit
fault
Remedy
Check,
clean
and
replace
spark
plugs,
if
required
Check
for
correctconnection
and
correct,
as
required
Cleam,
dry.
replace,
if
defective
Clean
breaker
contacts,
replace
and
adjust
contact
gap,
as
required
Check
for
correct
wiring
11.11.
Defect:
Electrical
Accessories
Cause
of
Defect
Remedy
a -
Alternator
not
charging
Check
brushes
and
replace,
if
required
Check
rotor
winding
for
continuity
(by
means
of
an
ohmmeter,
circuit
tester
etc.
Alternator
rotor
replacement
Check
for
correct
connection
of
leads
b
~
Starter
inoperative
Check
brushes
and
replace,
if
required
Check
battery
for
charge
Check
for
correct
connection
of
leads
Constact
manufacturer
or
replace
electrical
accessories,
if
not
succeeding
in
determining
cause
of
defect.
Issued
5/92