EasyManua.ls Logo

Peak i-Flow N2 - Technical Specification

Peak i-Flow N2
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 15
Technical Specification
Environment
Minimum Operating Ambient Temperature +5°C (41°F)
Maximum Operating Ambient Temperature +50°C (122°F)
Maximum Altitude 2000m
Maximum Relative Humidity 80% non-condensing
Minimum Storage Temperature -20°C (-4°F)
Maximum Storage Temperature +60°C (140°F)
When taken out of storage, the Generator should be allowed to acclimatize at room temperature for a
minimum of 3 hours before operation.
Generator Outlets
Required Inlet Air Pressure 145 / 116 /101 psig (10 / 8 / 7 barg)*
Maximum Inlet Air Pressure 145 psig (10 barg)
Minimum Inlet Flow Varies depending on model & configuration
Maximum Outlet Pressure 131 / 101 / 87 psig (9 / 7 / 6 barg)*
Maximum Outlet Flow Varies depending on model & configuration
N
2
Purity >99.9%
Electrical Requirements
Voltage 230 VAC ±10%
Frequency 50/60 Hz
Current (i-Flow) 2 A
Current (Dryer / Filtration) 2 A
Pollution degree 2
Installation category Class II
General
Skid Model 1 2 3 4 5
Dimensions mm (inches) W x D x H
2000 x 1400 x 2343 mm
(78.7 x 55.1 x 92.3 inches)
2240 x 1480 x 2460 mm
(88.2 x 58.3 x 96.6 inches)
Shipping weight kg(lbs) 805 (1775) 885 (1951) 985 (2172) 1215 (2677) 1365 (3009)