PCAN-Router DR – User Manual
24
CAN
Galvanic isolation CAN 1 is isolated up to 5 kV against CAN 2, RS-232,
and the power supply (compliant with IEC 60601-1)
CAN 2 and RS-232 are isolated with 500 V against
each other and against the power supply
Internal termination Switchable for each CAN channel, disabled at delivery
Listen-only mode Progammable; not activated at delivery
Time stamp resolution 1 μs
Signal delay for CAN
message routing
About 260 μs for CAN messages with an 11-bit ID
and eight data bytes at a nominal bit rate of 500 kbit/s
RS232
Bit rate max. 115200 Baud
Signal level max. ±14 V
Galvanic isolation Between RS-232,CAN2, and the power supply
isolated against max. 500V
Microcontroller
CPU LPC2119 (based on Arm® ARM7TDMI-S CPU)
Clock frequency 60 MHz
Voltages Core: 1.8 V; I/O: 3.3 V
RAM 128 kByte SDRAM
Firmware upload via CAN (PCAN interface required)
Measures
Dimensions 22.5 x 99 x 114.5 mm (W x H x D)
See also dimensional drawing in Appendix B
Weight 101 g
Environment
Operating temperature -40 … 85 °C (-40 … 185 °F)
Temperature for storage
and transport
-55 … 125 °C (-67 … 257 °F)
Relative humidity 15 - 90 %, not condensing
Ingress protection
(IEC 60529)
IP20