2. Restart the device by shortly disconnecting the power
supply or by pressing the Reset button into the hole with
the tip of small screwdriver or a paper clip.
The change of the rotary switch is now active.
The activated bootloader is indicated as follows:
LED Status
Status off
CAN 1 orange blinking
CAN 2 orange on
3. Continue with the chapter 5.3
Firmware Transfer
.
5.3 Firmware Transfer
The firmware is uploaded via a CAN bus using the Windows
program PEAK-Flash.
Note: The firmware transfer is only possible with the CAN 1
connector. This must be connected to the PC alone.
Do the following to transfer a new firmware with PEAK-Flash:
1. Connect the CAN interface of your computer to the CAN 1
connector on the PCAN-Router DR. Make sure that the CAN
cabling is terminated correctly (2 x 120 ).
2. Download the software PEAK-Flash, which is included in the
development package:
www.peak-system.com/quick/DLP-DevPack
3. O
pen the zip file and extract it to your local storage medium.
4. Run the PEAK-Flash.exe.
The program opens.