EasyManua.ls Logo

Peavey DPM C8 - 1.4 CHANGING PARAMETER VALUES

Peavey DPM C8
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.3
N
AVIGATING
WITHIN
A
SCREEN
When
a
parameter
is
highlighted
by
die
moveable
cursor,
that
parameter
is
available
for
editing.
There
are
three
main
ways
to
move
the
cursor:
the
four
arrow
buttons,
optional
mouse
(C8
only),
or
optional
trackball
(C8
only).
The
up/down
arrow
buttons
move
the
cursor
up
and
down
within
a
column
of
parameters.
The
left/right
arrow
buttons
move
the
cursor
left
and
right
if
a
screen
has
more
than
one
column
of
parameters.
For
screens
with
a
single
column
of
parameters,
the
left/right
buttons
move
the
cursor
vertically
and
also
allow
the
cursor
to
‘wrap
around”
from
the
top
to
bottom
or
bottom
to
top.
The
mouse
or
trackball
works
as
it
would
with
a
computer:
roll
the
mouse
or
trackball
to
move
the
cursor
to
a
particular
parameter.
1.4
CHANGING
PARAMETER
VALUES
To
change
a
parameter’s
value
after
selecting
it,
use
the
Inc/Dec
buttons,
data
wheel
(C8p
only),
direct
numerical
entry
or
the
data
slider
(the
default
is
slider
1,
but
any
other
slider,
or
none
at
all,
can
be
used,
see
Section
4.2
for
more
information).
Press
Inc
or
Dec
once
to
change
die
values
one
digit
at
a
time;
press
and
hold
die
button
to
scroll
dirough
values.
Shortcut:
To
accelerate
the
Inc
or
Dec
button
scrolling
speed,
press
the
other
button
while
holding
the
first
button.
Example:
To
speed
up
the
Inc
button
scrolling,
while
pressing
and
holding
Inc,
press
Dec.
For
direct
entry,
type
the
number
you
want
and
press
the
Enter
button
to
keep
it
or
the
Exit
button
to
cancel.
(The
field
will
blink
to
remind
you
that
you
must
press
either
of
these
buttons.)
To
enter
negative
numbers
(e
g..,
for
Transpose),
you
must
first
type
at
least
one
digit
of
the
number
to
get
into
numeric
entry
mode,
after
which
the
-/dec
button
will
toggle
the
number
between
negative
and
positive.
For
example,
to
enter
a
-48,
either
of
the
following
methods
is
acceptable:
Press
“4/
“8,”
Press
“4,”
V
“8”
With
a
mouse
or
trackball,
after
selecting
the
parameter,
click
and
hold
die
mouse/trackball’s
left
hand
button,
then
drag
the
mouse
up
(or
rotate
the
trackball
away
from
you)
to
increase
the
parameter
value,
or
drag
the
mouse
down
(or
rotate
the
trackball
toward
you)
to
decrease
the
value.
7.5
THE
ALL-IMPORTANT
EXIT
BUTTON
To
exit
from
any
screen
back
to
the
previous
screen,
press
the
Exit
button.
You
can
always
go
from
any
screen
back
to
the
main
Preset
selection
screen
by
repeatedly
pressing
Exit
until
die
main
Preset
selection
screen
appears.
7.5
T
HE
PANIC
BUTTON
If
a
device
receives
a
MIDI
note
on
message
without
a
corresponding
note
off
message,
that
note
can
become
“stuck”
on.
To
unstick
any
notes,
simply
press
the
Panic
button.
A
short
press
sends
a
MIDI
all
notes
off

Table of Contents

Other manuals for Peavey DPM C8