June 11, 2012 Version 1.6.4b.1 77
The behavior of the fault relay is summarized below.
Pin 25 is connected to pin 12
Pin 25 is connected to pin 13
Pin 25 is connected to pin 13
Pin 25 is connected to pin 13
Project erased / no project loaded
Pin 25 is connected to pin 13
Pin 25 is connected to pin 13
Connection
A 25-pin DSub connector (DB-25) is used for accessing the GPIO functions. Although you
can terminate GPIO functions directly to the DB-25 connector, we recommend that you use
the optional breakout accessory (GPIO-25: Peavey Part# 00510490).
The GPIO-25 is a convenient way to access each pin and facilitates easy rack wiring and
troubleshooting. The GPIO-25 is a DIN rail package and includes removable Euro connectors
for terminating the pins. A single DB-25 male/female cable connects the GPIO-25 to the
NION or CAB 4n.