Determining the sound levels and vibration rates is based on the operating conditions at the maximum nominal rating.
Maximum A-weighted sound pressure level (ref. 20 µPa) at the position of the user L
pA
= 84 dB(A) K = 2,5 dB(A)
C-weighted peak sound pressure (ref. 20 µPa) at the position of the user L
pC
< 130 dB(C)
Values dened as per sound measurement standards NF EN ISO 11201 and NF EN ISO 3744.
Symbol Value Unit Reference Comment
L
WAm
92 dB(A) 1 pW Measured sound power level
L
WAg
93 dB(A) 1 pW Guaranteed sound power level
The recording of the measured sound power level and of the guaranteed sound power level has been performed according to a
procedure in accordance with directive 2000/14/CE appendix V.
Excelion 2000
Model Version
Cutting head: ROLL CUT
Power in Watts 2000
Weight (excluding cutting tool and safety guard) in kg 5.4
Dimensions (l x w x h) in mm 1,800 x 450 x 225
Cutting diameter in mm 340
Rotational speed in rpm 2000 to 6200
Battery life Depending on the use and type of battery
Values measured at maximum rated speed
a
h
value
of the
right wrist
measured
in m/s²
a
h
value
of the
left wrist
measured
in m/s²
MultiCut
Ø2.4 wire 1.7 2.1
Ø3 wire 1.7 2
Twin-blade 1.5 1.3
8 teeth 2.4 2
RollCut
Ø2.4 wire 1 1.3
Ø3 wire 1.9 2
TapCut
Ø2.4 wire 3.8 3.2
Ø3 wire 3.5 3.5
BladeCut
Twin-blade 3.5 4.5
Trident 3.5 4.5
Mulching 2.7 2.1
Saw 2.6 2.4
CityCut Blades 1.2 1
Values measured at maximum rated speed in eco
mode
a
h
value
of the
right wrist
measured
in m/s²
a
h
value
of the
left wrist
measured
in m/s²
MultiCut
Ø2.4 wire 1.4 1.3
Ø3 wire 1.5 1.2
Twin-blade 1 0.9
8 teeth 1.9 1.5
RollCut
Ø2.4 wire 1 0.8
Ø3 wire 1.6 1.8
TapCut
Ø2.4 wire 4.4 3.5
Ø3 wire 3.6 2.7
CityCut Blades 1.1 0.8
Vibration emission values according to EN 60745-1, EN ISO 22867:
Measurement uncertainty: K = 1.5 m/s²
Measurement uncertainty: K = 1.5 m/s²