22 06/218390-017A
CODE #3: AMBIENT PROBE ALARM
LOCATE THE AMBIENT
PROBE CONNECTION ON
THE CONTROL BOARD
UNPLUG
THE PROBE,
INSPECT THE
CONNECTION &
CHECK ENTIRE
WIRE FOR
DAMAGE
SYSTEM IS
REPAIRED
IS THE WIRE
PLUGGED INTO
THE BOARD?
MAKE THE
REPAIR BY
REPLACING
THE PROBE OR
FIXING THE
CONNECTION.
DID THE
ALARM CODE
GO AWAY?
PLUG THE
PROBE BACK
INTO THE
CONTROL
BOARD.
DID THE
ALARM CODE
GO AWAY AFTER
PLUGGING THE
PROBE BACK IN?
TECH TIP:
THE PROBE WILL SENSE TEMPERATURE IN THE ROOM.
IF THE APPLIANCE IS CYCLING TOO MUCH, MOVE THE
PROBE FARTHER AWAY FROM THE APPLIANCE.
YESNO
NO NO
YES
YES
See next page for test locations and Readings.