PelPro Cast Pellet Stove • 7093-600 • 07/13/16 pelprostoves.com2 2
Troubleshooting
Troubleshooting
Power Related
In the event of a power outage:
• I f u si n g a g en erator, Pelpro recommen d s
a stead y state g en erator f or b est stove
perf orman ce.
• This stove needs 110v to run properly. This stove
h as n ot b een tested f or u se w i th a th i rd party
b attery b acku p.
Stove plugged in but no response
• Ch eck yo u r h ome’ s ci rcu i t b reake r
• Reset snap disc (located between drop tube and
hopper (Zone 2)
• V i su ally i n spect w i res, b low ers an d pow er cord
for breaks or wear to nd cause of possible short
circuit (Zone 2)
Component (i.e. blower) fails to start or fails to
turn off
• Ch eck all con n ecti on s an d pow er plu g s are secu re
• V i su ally i n spect w i res, b low ers an d pow er cord to
nd cause of possible short circuit
Pro Tip
Ch eck passag es to assu re
th ey are clear of ash an d
obstructions. Poor airow
lead s to poor perf orman ce
of yo u r stove.
Troubleshooting your stove
V i si t pelprostoves.com or scan th i s cod e:
A
A
1
Z o n e
1
Z o n e
2
Z o n e
2
Z o n e
3
Z o n e
3
Z o n e