Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Description
Ref. MKT-IM-012 / D - 03.02.2022 13 / 110
3 Description
3.1 Introduction to the Magnum Cv and Magnum IT valves series
The Magnum valve is available in several configurations:
Magnum Cv Magnum IT
Turbine External turbine Internal turbine
Inlet diameter 3.91cm (1½") 5.08cm (2")
Outlet diameter 3.91cm (1½") 5.08cm (2")
Drain diameter 3.91cm (1½") 3.91cm (1½")
Logix Magnum Time Clock 742/298
Logix Magnum Demand 762/298
Logix Magnum Time Clock 742F/293
Logix Magnum Demand 762F/293
5 - Cycle softener 3 - Cycle filter
C0: Service
C1: Backwash
C2: Brine draw
C3: Slow rinse
C5: Fast rinse
C8: Refill
C0: Service
C1: Backwash
C5: Fast rinse
Info
Both valves configuration (293 & 298) are available with Magnum Cv and Magnum IT
series.