ENGLISH
EVERPURE
®
H-Series Water Filtration Systems 7
Systems Tested and Certified by NSF International
against NSF/ANSI Standards 42, 53 and NSF 401 of
claims specified on the Performance Data Sheet.
*NSF Standard 401 have been deemed as “incidental
contaminants/emerging compounds”. Incidental
contaminants are those compounds that have been
detected in drinking water supplies at trace levels.
While occurring at only trace levels, these compounds
can affect the public acceptance/perception of drinking
water quality.
2. VERIFY UNDERSINK MOUNTING LOCATION
Measure 22” from the base of the cabinet, and mark the
mounting location for the top of the filter head. Measure
13” for the width required for the H-1200 System with
dual cartridges. Make sure there is adequate space above
the head to open and close the shut-off valve and to avoid
crimping the water line tubing. Also, make sure your
chosen location offers easy access for future cartridge
changes.
DIMENSION
Width Height Depth
H-1200 13" 22" 5"
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. MOUNT FILTER HEAD UNDER SINK
A. Identify Dual Filter Head and Shut Off Valve (EV309860).
B. Apply Plumbers Tape to the threads on the inlet (left)
side of the Head. Screw on the new Shut Off Valve
and hand tighten. Repeat for the Stainless Coupler
(EV312350) for the outlet (right) side of the Head.
C. Apply Plumbers Tape to the threads of the Outlet
Elbow Fitting (black band). Screw into the outlet of
the Stainless Coupler. Wrap tape in direction of the
threads to assure a tight fit and avoid small leaks.
D. Securely mount the filter head on the cabinet wall
using the enclosed mounting screws and washers.
4. Go to page 5 and follow Basic Installation Instructions,
Steps 4, 5, and 6, to complete the H-1200 System
installation.
CLAIMS & NOTES
This installation must comply with all applicable state and
local regulations.
Do no use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may
be used on waters that may contain filterable cysts.
Testing was performed under standard laboratory
conditions, actual performance may vary.
EPA Est. No. 002623-IL-002
3
A
D
Dual Filter Head Shut Off Valve
C
B
2
22"