8 • FLECK 2815 Control Valve Service Manual
3200, 3210 REGENERATION CYCLE
SETTING PROCEDURE
How To Set The Regeneration Cycle Program
The regeneration cycle program on your water conditioner has
been factory preset, however, portions of the cycle or program
may be lengthened or shortened in time to suit
local conditions.
3200 Series Timers
NOTE: Always remove the meter cable from the meter cap
before opening the timer door.
1. To expose cycle program wheel, grasp timer in upper left-
hand corner and pull, releasing snap retainer and swinging
timer to the right.
2. To change the regeneration cycle program, the program
wheel must be removed. Grasp program wheel and squeeze
protruding lugs toward center, lift program wheel off timer.
Switch arms may require movement to facilitate removal.
3. Return timer to closed position engaging snap retainer in
back plate. Make certain all electrical wires locate above
snap retainer post.
Timer Setting Procedure
How To Change The Length Of The Backwash Time
The program wheel as shown in Figure 6 is in the service
position. As you look at the numbered side of the program
wheel, the group of pins starting at zero determines the length
of time your unit will backwash.
For example, if there are six pins in this section, the time of
backwash will be 12 min. (2 min. per pin). To change the length
of backwash time, add or remove pins as required. The number
of pins times two (x2) equals the backwash time in minutes.
How To Change The Length Of Brine And Rinse Time
1. The group of holes between the last pin in the backwash
section and the second group of pins determines the length
of time that your unit will brine and rinse (2 min. per hole).
2. To change the length of brine and rinse time, move the rapid
rinse group of pins to give more or fewer holes in the brine
and rinse section. Number of holes times two (x2) equals
brine and rinse time in minutes.
How To Change The Length Of Rapid Rinse
1. The second group of pins on the program wheel determines
the length of time that your water conditioner will rapid
rinse (2 min. per pin).
2. To change the length of rapid rinse time, add or remove pins
at the higher numbered end of this section as required. The
number of pins times two (x2) equals the rapid rinse time
in minutes.
How To Change The Length Of Brine Tank Refill Time
1. The second group of holes in the program wheel determines
the length of time that your water conditioner will refill the
brine tank (2 min. per hole).
2. To change the length of refill time, move the two pins at the
end of the second group of holes as required.
3. The regeneration cycle is complete when the outer
microswitch is tripped by the two pin set at end of the brine
tank refill section.
4. The program wheel, however, will continue to rotate until
the inner micro switch drops into the notch on the
program wheel.
61502-3210 Rev A
Figure 6