EasyManua.ls Logo

Pentair FLECK 5600 - Table of Contents; Job Specification Sheet

Pentair FLECK 5600
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TABLE OF CONTENTS
JOB SPECIFICATION SHEET ...............................................2
INSTALLATION .....................................................................3
START-UP INSTRUCTIONS..................................................4
MODEL 5600 INSTALLATION AND
START-UP PROCEDURES ....................................................4
MODEL 5600 BACKWASH FILTER INSTALLATION AND
START-UP PROCEDURES ....................................................5
MODEL 5600 INSTALLATION AND
START-UP PROCEDURES ....................................................6
WATER CONDITIONER FLOW DIAGRAMS ...........................7
MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY ...........10
5600 ELECTROMECHANCIAL ............................................ 16
5600 VALVE ACCESSORIES ...............................................17
5600 VALVE ASSEMBLIES .................................................18
SERVICE INSTRUCTIONS ..................................................21
TROUBLESHOOTING ..........................................................24
GENERAL SERVICE HINTS FOR METER CONTROL ..........25
MODEL 5600SF TROUBLESHOOTING ...............................25
JOB SPECIFICATION SHEET
Job Number: ______________________________________________
Model Number: ____________________________________________
Water Hardness: __________________________________ ppm or gpg
Capacity Per Unit: __________________________________________
Mineral Tank Size: ___________ Diameter: ________Height: ________
Salt Setting per Regeneration: ________________________________
1. Type of Timer:
A. Time Clock
B. Meter Initiated
2. Downflow: Upflow Upflow Variable
3. Meter Size:
A. 3/4-inch Turbine
B. 3/4-inch Paddle Wheel
C. Electronic ____Pulse Count ___ Meter Size ____________
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or
Delayed Regeneration
B. System #4: Time Clock
5. Timer Program Settings:
A. Backwash: ______________________________ Minutes
B. Brine and Slow Rinse:_____________________ Minutes
C. Rapid Rinse: ____________________________ Minutes
D. Brine Tank Refill: ________________________ Minutes
E. Pause Time: ____________________________ Minutes
F. Second Backwash: _______________________ Minutes
6. Drain Line Flow Control: gpm
7. Brine Line Flow Controller: gpm
8. Injector Size#:
CALIFORNIA PROPOSITION 65 WARNING
WARNING:
This product contains chemicals known to
the State of California to cause cancer or
birth defects or other reproductive harm.
2FLECK
5600 Service Manual

Related product manuals