User Guide Fleck 5800-XTRi-XTR-SXT-LXT
6 / 76 Ref. MKT-UG-054 / A - 03.06.2022
3 . Description
3.1. Technical specifications
Pressure: ..........................................................Hydrostatic: 20 bar; Working: 1.4 - 8.6 bar
Maximum service flow rate (ΔP 1.7 bar): .........6.1 m
3
/h
3.2. Environmental conditions
Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C;
main supply voltage fluctuations up to ±10% of the nominal voltage;
temperature from 0 °C to 52 °C;
not directly exposed to the sun;
installed in a dry place.
3.3. Description and components location
Inlet
Meter
Outlet
Drain
Brine
Display
Mixing device
Regeneration button
Up button
Display
Down button
Down button
Display
MODE button
Up button
XTRi & XTR controllers
LXT controllerSXT controller
All controllers
Fleck_5800-XTR2_UG_VV_Multilingual.book Page 6 Mardi, 12. juillet 2022 10:34 10