User Guide Fleck 5800-XTRi-XTR-SXT-LXT
10 / 76 Ref. MKT-UG-054 / A - 03.06.2022
Current day of the week
Note: Determine the day of regeneration (1 for Monday, 2 for Tuesday, 3 for Wednesday,
4 for Thursday, 5 for Friday, 6 for Saturday and 7 for Sunday).
4.2.2. Diagnostic mode
To access the recorded informations, press and simultaneously for 5 seconds. Press to see the next data. Press to
exit the diagnostic mode.
4.3. LXT controller
Note: The controller must be plugged to be programmed.
After 5 minutes without any button pressed, the unit returns to normal operation without saving.
4.3.1. Basic programming
Note: Menus are displayed by pressing MODE.
Time of day
Note: Determine the time of day.
Regeneration time
Note: Determine the time of regeneration.
Water Hardness or number of days between regenerations
Note: Determine the water hardness in mgl (metered) or the number of days between regenerations (time clock).
J Adjust the day of the week with and .
K Press to validate the selection.
A Press MODE until display position point to the Time of Day icon.
B Press and hold or until the Programming icon appears.
C Set the time with or .
D Press to validate the selection and return to the service mode.
A Press MODE until display position point to the Time of Regeneration icon.
B Press and hold or until the Programming icon appears.
C Set the time with or .
D Press MODE to go to the next parameter, or press to validate the selection and
return to the service mode.
A Press MODE until display position point to the Hardness or Days between
regenerations icon.
B Press and hold or until the Programming icon appears.
C Set the water hardness or the number of days between regenerations with or
.
D Press MODE to go to the next parameter, or press to validate the selection and
return to the service mode.
Fleck_5800-XTR2_UG_VV_Multilingual.book Page 10 Mardi, 12. juillet 2022 10:34 10