Press hardness to adjust the hardness setting. This value should match the
hardness of the incoming untreated water supply. Press to save your
changes or press to return to the home screen.
Note: Changing the hardness setting recalculates treatment
volume and regeneration interval.
4.1.2. Diagnostic mode
Press from the home screens to view the diagnostic screen. Press the screen navigation arrows at the upper-right and left
of the screen to view each diagnostic parameter. Press to return to the home screen.
4.2. SXT controller
Note: The controller must be plugged to be programmed.
After 5 minutes without any button pressed, the unit returns to normal operation without saving.
4.2.1. Basic programming
Note: Menus are displayed in a defined and incremental order.
Day of Override
Note: Determine the maximum number of days of operation without regeneration.
Regeneration time
Note: Determine the time of regeneration.
Feed Water Hardness
Note: Determine the feed water hardness in °tH.
Reserve capacity
Note: Determine the reserve capacity in Litre or in percentage.
A Press and simultaneously for 5 seconds to enter the menus sequence.
B Select the number of days of Override with and .
C Press to validate the selection and advance to the next parameter.
D Adjust the regeneration time with and .
E Press to validate the selection and advance to the next parameter.
F Adjust the water hardness with and .
G Press to validate the selection and advance to the next parameter.
H Adjust the reserve capacity with and .
I Press to validate the selection.
Settings
hardness
300 mg/L
Fleck_5800-XTR2_UG_VV_Multilingual.book Page 9 Mardi, 12. juillet 2022 10:34 10