Assistance interval screen
Use the assistance interval screen to set the interval. The controller will
display a message telling that the system need a service (optional). The
assistance interval can be based on a set number of months (month based) or
a number of regenerations (regen based).
Press the
interval button to select a month-based or regen-based
assistance interval, then press . Press either the
month or regen.
button (depending on your previous selection), and select the number of
months (up to 60) or regenerations (up to 2000) until the homeowner will
need to call for service;
press to validate the selection and move to the home screen.
Home screen
On the upper left corner, the
day and time button allows to update the
current day and time. Theupper right corner indicates the remaining time or
volume to next regeneration. On the middle circle, the green box indicates the
current cycle step. The buttons down on the right allow to navigate through the
different screens. From left to right, we have:
vacation, assistance,
diagnostics, settings and regeneration.
Day and time screen
Press the
day of week, hour, minute, and AM/PM/HR buttons to adjust
the values to the correct day of week and time. Setting the value of the
AM/
PM/HR
button to HR changes the display to a 24 hour clock. Press the day,
month, and year buttons to adjust the values to the correct date. Press
when finished to return to the home screen. Press to return to the home
screen without saving.
Settings screen
Press to access the settings screen.
Bluetooth turns ON the bluetooth
signal. Must be turn OFF, except for XTRi controller to open Bluetooth signal
during programming. It will automatically turn to OFF when WiFi is connected.
Press
day override/time-driven to adjust the number of days since last
regeneration in which a new regeneration will automatically be run whether
one is scheduled or not. Press
regen. time to adjust the time of day that an
automatic regeneration cycle will begin.
Press
and to switch screens.
Assistance/Mainten. Interval
month
month
based
1
interval
wed
12:01 am
4.5
m
3
Water Treatment
treatment
tank refill
rapid rinse
backwash
draw
Day And Time
17 jan 15
12 01 pm
sat
Settings
day override/
time-driven
Bluetooth
off
1 d
02:00 am
regen. time
Fleck_5800-XTR2_UG_VV_Multilingual.book Page 8 Mardi, 12. juillet 2022 10:34 10