User Guide Foleo
16 / 116 Ref. MKT-UG-038 / D - 15.11.2019
7 . Operation
7.1. Display during operation
7.2. Display during regeneration
During regeneration, the regeneration cycle wheel shows the regeneration step the valve is advancing to, or has reached
(green), and the time remaining in that step (1). Once all regeneration steps are complete the valve returns to treatment position
and resumes normal operation. The time remaining in regeneration will be displayed on the home screen in hours and minutes.
Pressing the button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes
normal step timing. The button is only shown when the valve is in position and the motor has stopped.
7.3. Manual regeneration
From the home screen, press the regeneration button to access the regeneration screen.
Press
now to begin a regeneration immediately, or press at regen. time to queue the regeneration for the programmed
regeneration time (2:00 AM default for softeners, 12:00 AM default for filters). Pressing at regen. time again will cancel the
manual regeneration.
Water treatment
wed
12:01 am
4.5
m
3
treatment
rapid rinse
backwash
tank refill
pause
draw
Regeneration
48 m
34 s
treatment
rapid rinse
backwash
tank refill
pause
draw
Regeneration
now
at regen. time