MAGICSTREAM
®
Laminar Installation and User’s Guide MAGICSTREAM
®
Laminar Installation and User’s Guide
27
Troubleshooting (IntelliBrite
®
Controller)
Troubleshooting (MagicStream
®
Laminar)
Symptom Action
The light will not
illuminate.
Check the GFCI ground fault wiring and reset if
necessary.
Light does not function
properly.
Check the light wiring connection to the junction
box at the pool side and to the AC power switch.
Be sure that there is proper AC power applied
to the light.
What Mode is the light
in?
Turn the switch Off/On 17 times. This will put the light in
IntelliBrite Mode, fixed on white, Random Mode off and
Thumper on. From there you can set the desired mode. See
page 6.
Symptom Action
Both of the LEDs are
flashing.
The IntelliBrite Controller has detected that the load has
exceeded the maximum allowable wattage or the output is
shorted out
1. Switch off the IntelliBrite Controller OFF. Remove
excessive load or short.
2. Press the IntelliBrite Controller power switch to power on
the unit. Ensure that the LEDs are no longer flashing.
The light will not
illuminate.
Check the ground fault wiring and reset if necessary.
Light does not function
properly.
Check the light wiring connection to the junction box at the
pool side and to the main circuit breaker.
Be sure that there is proper AC power applied to the light.