5. OPERATION COMFORT MODE [ ]
5.1 Getting started
Note: the square moves over the different symbols
when programming. The symbol in the square
indicates the active function: manual mode, automatic
mode by external signal, booster function.
The display illuminates and shows all features. Then it
shows the setting temperature and sensor mode. The
sensor mode is initialised automatically. If the floor
sensor cable is connected, it operates in floor sensor
mode. If the floor sensor cable is not connected, it
operates in room sensor mode.
After 5 sec. the thermostat checks if an external
control signal is connected.
If yes, the thermostat will be controlled according to the
set temperature and external signal. The symbol AUTO
is activated. If not, the thermostat will be controlled
according to the set temperature.
Adjust the set temperature, desired floor temperature
or room temperature, with the <
> buttons.
This is an approximate set value to get a comfort
temperature on the floor or in the room.
Heating-on symbol <
> indicates on the display when
the heating cable is on.
Choose another program
• Use the <
> buttons to scroll through the
menu and activate P.
• The display switches to this view: ; P is
flashing.
• Confirm by pushing OK button to go in program
selection; Co is flashing.
• Select program EcoHome, EcoOffice or Standby
mode by
• using <
> buttons and confirm by pressing
<
>.

Table of Contents