Menu 6:
Maximum temperature set point for the room sensor
Change the temperature value with <
> buttons
Confirm by pressing <
> button.
Possible values:
from 5°C [5.0] to 40°C [40.0]
(room regulation)
from 5°C [5.0] to 35°C [35.0]
(floor regulation)
Factory value:
40.0°C (room regulation)
35.0°C (floor regulation)
Menu 7:
Minimum temperature set point for the floor sensor
Change the temperature value with <
> buttons
Confirm by pressing <
> button.
Room regulation mode:
Not possible to set min. floor
temperature limit
Room sensing with limiter
floor regulation mode:
Possible values: from 5°C [5.0]
to 15°C [15.0]
Factory value : 5.0°C
Menu 8:
Maximum temperature set point for the floor sensor
This value is the max. limit value for the floor sensor
in room sensing mode with floor limiter.
Change the temperature value with
<
> buttons.
Confirm by pressing <
> button.
Room regulation mode:
Not possible to set max. floor
temperature limit