1. TECHNICAL SPECIFICATIONS
Supply voltage 230VAC, +10%,
–15%, 50/60 Hz
Power consumption, average 4 VA
Main power switch 2-pole
Relay output - heating cable 230V, max. 13A
Ambient temperature – operation 0 +40°C
Ambient temperature – transport –20 +50°C
Temperature range, floor sensor +5 +35°C
Temperature range, room
sensor
+5 +40°C
Accuracy – floor/room sensor ± 0,5°C
Switching hysteresis 0,5°C (Factory settings
adjustable between
0,2-2.0°C)
Control modes Floor sensor
Room sensor
Room sensor with floor
sensor as a limiter
(Not in Comfort mode
)
Economy programs
EcoHome; EcoOffice
2 preset-programs;
editable in time blocks of
30 min
Back-up for set values In non-volatile memory
Back-up for time and date 24 hours
Optional external control Set back function
–3.5°C (Not in programs
EcoHome and EcoOffice)
Protection class IP 21
Terminals Max. 2,5 mm
2
Floor sensor with 3 m cable NTC, 10K / 25°C.
Maximum length of floor sensor
cable
100 m, 2 x 1,5 mm
2
(230VAC cable type)
Dimension with frame (Fig.1) H 82 x W 82 x D 57 mm
Colour Polar white RAL 9010
Approvals Semko, VDE, eu.bac, CE