MANUAL REGENERATION
Delayed Regeneration
Press and release
to program a delayed regeneration. The
system will regenerate at the next Time of Regeneration
(2:00 AM). Repeat procedure to disable the Delayed Regen.
Regen dot blinks when delayed regeneration is on.
Immediate Regeneration
Press and hold the
for 3 seconds to initiate an immediate
regeneration. The control cycles to backwash. The control
will proceed through a complete regeneration. A cascading
symbol (- -) will be displayed until regeneration is complete.
The symbol (- -) is not displayed during a quick cycling of the
control.
Figure 15
QUICK CYCLING THE CONTROL
Quick Cycling
Press and hold the
for 3 seconds to initiate an immediate
regeneration. The control will cycle to the backwash cycle.
1. Press and release the
to display "C 1"
2. Simultaneously press then release
and to move the
control to the next cycle.
NOTE: The time may be displayed for 5 seconds.
3. Press and release the
to display "- -" or the "C#".
Continued pressing of
will switch the display between
"- -" and "C#".
4. Repeat steps 2 and 3 to cycle through each position.
Quick Cycle to Service Position
Simultaneously press
and and hold for 3 seconds during
any regeneration cycle. The control will skip the remaining
regeneration cycles and return to the service position. The
Time of Day will be displayed when the control reaches the
service position.
Figure 16
CYCLE DEFAULTS TABLE
Recharge Cycles:
Table 1 Length of Cycle Time remaining to
end of cycle
Cycle Cycle
Description
HE
Setting
HC
Setting
HE
Setting
HC
Setting
1 Backwash 1 10 min 10 min 76.6 min 105.6
min
2 Brine Draw
55 min 74 min 66.6 min 95.6 min
Slow Rinse
3 Re-
Pressurize
3 min 3 min 11.6 min 21.6 min
4 Fast Rinse 1 4 min 4 min 8.6 min 18.6 min
5 Backwash 2 1 min 1 min 4.6 min 14.6 min
6 Fast Rinse 2 1 min 1 min 3.6 min 13.6 min
7 Rell 2.6 min 12.6 min 2.6 min 12.6 min
*The camshaft does not move between Brine Draw and Slow Rinse.
Slow Rinse begins when the brine in the salt tank runs out and the
check valve closes.
Recharge Cycle Requirements:
Minimum Salt/
Capacity
HE
Maximum Salt/
Capacity
HC
Salt/Recharge
(lbs)
2.6 12.8
Recharge Time
(min)
75 109
Water to Drain
(gal)
37 44
Max. Flow to Drain
(gpm)
1.7 1.7
OM26K • 11