EasyManua.ls Logo

Pentair Pool and Spa Control System SunTouch - Equipment Location

Pentair Pool and Spa Control System SunTouch
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
SunTouch Pool and Spa Control System Installation and Users Guide
Plumb the solar feed and return lines between the filter and the heater. Install a three-port valve at the
feed line. Use a solar valve (P/N 263047)), to allow automatic draining of the panels.
A solar booster pump should be used when the distance to the panels exceed 200 ft., or the panels are
elevated higher than 25 ft.
Glazed solar panels require a drain valve to allow draining of the panels. This prevents damage from
overheating water. Install a drain valve at the solar feed line and connect to the pool fill line.
Equipment Location
All equipment, with the exception of the spa-side remote, must be located at least 10 ft. from the waters
edge.
INTELLICHLOR
SUNTOUCH
POWER CENTER
Recommended Hydraulic Schematic for Shared Equipment System
8
9
10

Table of Contents

Related product manuals