IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTALLATION AND
USER’S GUIDE
WHISPERFLOXF
®
VS AND
MAX-E-PROXF
®
VS
COMMERCIAL VARIABLE SPEED PUMP

Questions and Answers

  • M
    Maureen HudsonAug 17, 2025
    What to do if my Pentair WHISPERFLOXF VS fails to start?
    • D
      Dawn DavisAug 17, 2025
      If your Pentair Water Pump fails to start, there are several potential causes: * **Main voltage is not present:** Replace the fuse or reset the breaker/GFCI. Also, tighten the main wire connections. * **Pump shaft is locked:** Check if the pump can be rotated by hand and remove any blockage. * **Pump shaft is damaged:** In this case, the pump needs to be replaced.
  • R
    Russell BarrettAug 20, 2025
    What to do if my Pentair WHISPERFLOXF VS Water Pump has inadequate circulation?
    • R
      Robert HunterAug 20, 2025
      Inadequate circulation in your Pentair Water Pump can stem from: * **Dirty filter or pump basket:** Check the pump strainer basket and clean it if clogged. Also, inspect and clean the pool filter. * **Suction/discharge piping is too small:** Increase the piping size. * **Speed is set too slow:** Increase the filtration run time.
  • D
    Donna Mcmahon MDAug 22, 2025
    What to do if my Pentair WHISPERFLOXF VS Water Pump runs then stops?
    • T
      tommyoneillAug 22, 2025
      If your Pentair Water Pump runs and then stops, consider the following causes: * **“0004” over-temperature alarm:** Check that the back of the pump is free from dirt and debris. Use compressed air to clean it. * **“0017” over-current alarm:** Inspect the drive to motor connection terminals.
  • C
    Catherine AndersonAug 26, 2025
    Why Pentair WHISPERFLOXF VS has reduced capacity and/or head?
    • R
      Rachel PeckAug 26, 2025
      Reduced capacity and/or head in your Pentair Water Pump can be due to: * **Air pockets or leaks in suction line:** Check the suction piping and valve glands on any suction gate valves. Secure the lid on the pump strainer pot and be sure the lid gasket is in place. Check the water level to be sure the skimmer is not drawing air. * **Clogged impeller:** Turn off electrical power to the pump, disassemble, and clean debris from the impeller. If debris cannot be removed: remove the left hand thread anti-spin bolt and O-Ring, remove, clean, and reinstall impeller, and reassemble. * **Pump strainer basket clogged:** Clean the suction trap and pump strainer basket.
  • K
    Kathryn MillsAug 28, 2025
    What causes electrical problems in Pentair Water Pump?
    • J
      Jonathan ShannonAug 28, 2025
      Electrical problems in a Pentair Water Pump can manifest as: * **“000E” low voltage alarm:** Check the voltage at the motor terminals and at the panel while the pump is running. Check for loose connections. * **“0017” overheat alert:** Check the line voltage; if it's less than 90% or more than 110% of the rated voltage, consult a licensed electrician. Increase ventilation, reduce ambient temperature, and inspect the drive to motor connection terminals. If the motor runs too hot, turn the power off and check for proper voltage and impeller rubbing.
  • L
    laura73Aug 31, 2025
    What to do if Pentair WHISPERFLOXF VS does not respond to external controls?
    • J
      johnny94Aug 31, 2025
      If your Pentair Water Pump does not respond to external controls, ensure that the digit input cable is connected at both ends.
  • M
    Matthew CardenasSep 3, 2025
    Why is my Pentair WHISPERFLOXF VS noisy?
    • T
      Thomas BurgessSep 3, 2025
      A noisy Pentair Water Pump can be caused by several factors: * **Debris in contact with fan:** Ensure the back of the pump is free from dirt and debris. Use compressed air to clean it. * **Debris in strainer basket:** Clean the pump strainer basket. * **Loose mounting:** Check that the mounting bolts of the pump are tight.
  • M
    misty38Sep 5, 2025
    What to do if my Pentair WHISPERFLOXF VS Water Pump fails?
    • C
      Chase SanchezSep 5, 2025
      If your Pentair Water Pump fails, consider these potential causes: * **Air leak in suction:** Check the suction piping and valve glands on any suction gate valves. Secure the lid on the pump strainer pot and ensure the lid gasket is in place. Check the water level to be sure the skimmer is not drawing air. * **Not enough water:** Ensure the suction lines, pump, strainer, and pump volute are full of water. Be sure the valve on the suction line is working and open. Check the water level to ensure water is available through the skimmer. * **Pump strainer basket is clogged:** Clean the pump strainer basket. * **Pump strainer gasket is defective:** Replace the gasket.
  • S
    Susan RobinsonSep 8, 2025
    What to do if my Pentair WHISPERFLOXF VS runs without flow?
    • V
      vanessa53Sep 8, 2025
      If your Pentair Water Pump runs without flow, check these potential issues: * **Impeller is loose:** Check that the pump is spinning by looking at the fan on the back of the motor. If so, check that the pump impeller is correctly installed. * **Air leak:** Check plumbing connections and verify they are tight. * **Clogged or restricted plumbing or strainer basket:** Check for blockage in the strainer basket or suction side piping. Check for blockage in discharge piping, including a partially closed valve or dirty pool filter.
  • K
    Kelsey BriggsSep 12, 2025
    What does “LoFlo” or “HiFlo” alarm mean on Pentair WHISPERFLOXF VS Water Pump?
    • R
      rubiokristySep 12, 2025
      The “LoFlo” or “HiFlo” alarm on your Pentair Water Pump indicates that the flowmeter 20-set setting is too high (Low Flow alarm) or too low (High Flow alarm). To resolve this, clean the pool filter, pump strainer basket, and all skimmer baskets.

Summary

Important Safety Instructions

General Warnings

General safety precautions and warnings for pump operation and maintenance.

Suction Entrapment Hazards

Details risks of body or limb entrapment due to suction.

Mechanical Entrapment Risks

Describes risks of entrapment by moving parts or openings.

VGB Pool Safety Act Compliance

Outlines compliance requirements for commercial pool suction fittings.

Electrical Controls Installation Guidance

Guidance for installing electrical controls at the equipment pad.

Hazardous Pressure During Startup

Alerts to dangers of pressurized systems during startup and servicing.

Introduction to Pentair Variable Speed Pumps

Pump Overview and Functionality

Brief description of the pump's capabilities and purpose.

Motor Features and Design

Highlights the motor's characteristics for commercial applications.

Drive Assembly and Keypad Interface

Explains the VFD and user interface for speed control.

Drive System Features and Efficiency

Lists advanced features of the drive system, like efficiency.

External Control Methods

Describes methods for controlling the pump via external systems.

Using the Pumps Drive Keypad

Keypad Buttons and LED Indicators

Explains the role of each button and indicator on the keypad.

Pump Installation Procedures

Location Requirements and Placement

Specifies ideal placement criteria for the pump.

Piping and Plumbing Guidelines

Provides recommendations for suction and return piping.

Fittings and Valves Installation

Details installation of valves and fittings for proper function.

Electrical Installation Requirements

States compliance with electrical codes for installation.

Electrical Installation Details

Wiring and Connection Procedures

Instructions and safety warnings for connecting pump wiring.

Grounding and Bonding Practices

Explains essential grounding and bonding practices for safety.

External Control via RS-485 Communication

RS-485 Wiring and Configuration Steps

Steps for connecting and configuring the pump for RS-485 control.

External Control via Digital Inputs

Digital Input Wiring Kit Setup

Instructions for wiring using digital input kits.

Utilizing Pump Output Signal

Describes using the pump's output signal for external control.

Using External Input Signals

External Control Only Mode Operation

How to enable/disable mode for external control priority.

Pump Operation and Programming

Setting Clock and Pump Address

Guide to setting the internal clock and pump address.

Default Operational Schedule

Description of the pre-set operational schedule.

Programming Custom Schedules

Instructions for creating user-defined operating schedules.

Program Priority Logic

Explains the hierarchy of programmed schedules when not using external control.

Priming the Pump

Priming Procedure Steps

Detailed steps for priming the pump before initial startup.

Priming Adjustment Settings

Adjusting Priming Speed and Duration

How to set and modify the pump's priming speed.

Operating the Pump While Running

Quick Clean Feature Usage and Adjustment

How to use and temporarily adjust the Quick Clean function.

Quick Clean Programming and Keypad Security

Keypad Lockout Functionality

How to lock and unlock the keypad for security.

Factory Reset Procedure

Instructions for resetting the pump to factory default settings.

Operating the Pump in Flow Mode

Flow Mode Setup and Configuration

Guide for setting up and configuring flow mode operation.

Adjusting Flow Settings and Auto-Tuning

How to adjust flow percentage and perform auto-tuning.

Maintenance Procedures

Strainer Basket Cleaning

Steps for cleaning the pump's internal strainer basket.

Winterizing the Pump

Guidance for protecting the pump from freezing conditions.

Motor and Drive Component Care

Best practices for protecting the motor and drive components.

Pump Disassembly Guide

Step-by-step instructions for taking the pump apart.

Shaft Seal Replacement and Pump Reassembly

Shaft Seal Replacement Procedure

Detailed steps for replacing the pump's shaft seal.

Pump Reassembly Instructions

Steps for putting the pump back together after servicing.

Replacing the Drive Assembly

Removing the Existing Drive Assembly

Procedure for detaching the old drive assembly.

Installing the New Drive Assembly

Procedure for attaching a new drive assembly.

Troubleshooting Pump Issues

Pump Failure and Start-up Problems

Troubleshooting for pump not priming or failing to start.

Reduced Capacity and Head Issues

Addressing problems with low flow or head.

Flow, Noise, and Control Issues

Troubleshooting for pump running without flow, noise, or external control problems.

Electrical and Overload Faults

Diagnosing electrical faults, low voltage, and over-current alarms.

Understanding Faults and Alarms

Fault Code Descriptions and Causes

Explanation of various error codes displayed by the drive.

Replacement Parts Catalog

Parts Identification and Part Numbers

A catalog of available replacement parts with numbers.

Technical Data and Specifications

Performance Curves and Dimensions

Graphs and diagrams detailing pump performance and size.

Electrical and Mechanical Specifications

Lists voltage, amp, speed, and environmental specifications.

Pentair WHISPERFLOXF VS Specifications

General IconGeneral
ModelWHISPERFLOXF VS
Horsepower1.5 HP
Voltage230V
TypeVariable Speed Pump
EfficiencyEnergy Efficient
WeightVaries by model
Port Size2 inch