PerkinElmer Clarus 600/560 D MS Specifications

General IconGeneral
AnalyzerQuadrupole
DetectorElectron Multiplier
Vacuum SystemTurbomolecular pump
TypeGas Chromatograph Mass Spectrometer (GC-MS)
Ion SourceElectron Ionization (EI)
GC CompatibilityPerkinElmer Clarus GC series (560, 600)
ResolutionUnit resolution (0.5 to 2.5 amu peak width)
Operating Temperature15°C to 35°C
Power Requirements100-240 VAC, 50/60 Hz

Summary

Warnings and Safety Information

Conventions Used in this Manual

Explains text formatting, symbols, and cautionary notes for clarity and proper use of the manual.

Clarus MS Safety Practices

Outlines essential safety guidelines and general warnings for operating the Clarus MS instrument.

Compressed Gases

Details safety precautions and handling procedures for compressed gases used with the instrument.

Temperature, Humidity and Environment

Specifies environmental conditions required for safe and optimal instrument operation.

Safety Requirements

Lists critical safety requirements for gas delivery lines, cylinders, and ventilation.

Introduction

Preface

Introduces the Clarus MS as a benchtop mass spectrometer and its system components.

System Overview

Provides a high-level overview of the Clarus MS system components.

About the Clarus 600/560 D System

Clarus 600/560 D GC

Describes the Clarus 600/560 D Gas Chromatograph and its features and configurations.

GC Interface (Transfer Line)

Details the function and temperature control of the GC interface transfer line.

Ion Optics Path

Explains the components and function of the ion source, mass analyzer, and detector.

Vacuum System

Outlines the vacuum system, including the rotary pump and its function.

Maintenance

Typical Overall Maintenance Schedule

Provides a schedule for routine maintenance tasks, categorized by frequency (daily, weekly, monthly).

Leak Checking

Details the procedure for checking the integrity of the vacuum system for leaks.

Replacing a Filament

Step-by-step instructions for replacing the instrument's filament.

Mass Analyzer Maintenance

Covers the maintenance procedures for the mass analyzer components.

Troubleshooting

Overview

Identifies common sources of problems in gas chromatography and mass spectrometry operations.

Troubleshooting Chart

A table listing common problems, their probable causes, and recommended solutions.

Chromatography Related

Lists problems and solutions specific to chromatographic performance and issues.

Spectral Related

Addresses issues related to spectral data quality, interpretation, and calibration.