EasyManua.ls Logo

Perkins 403C-11 - Wiring Diagram 40 Amp Alternator - 403 C

Perkins 403C-11
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green 109
400 Series
Wiring diagram 40 amp alternator - 403C-11
Wiring diagram maximum circuit resistance
The resistance of battery cables 1,2 and 3 must not exceed 0.0018
³.
(1) Max current draw for standard oil pressure switch is 0.42 amps (5 Watt lamp max).
Circuit
Cable
number
Circuit current
Maximum circuit
resistance
Maximum cir-
cuit
volt drop
Remarks
Alternator
charging
40 amp 0.0125
³s0.5 Volt
See Glow Plugs
Circuit
Starter motor
solenoid
15.75 amp 0.04
³s0.63 Volt
See Glow Plug
Circuit
STD glow plugs
(via glow signal)
(Peak max)
39 amp
0.0128
³s0.5 Volt
1 Alternator warning lamp
2 Alternator
3 Battery
4 Starter motor
5 Oil pressure warning lamp
6 Oil pressure switch
(1)
7 Water temperature warning lamp
8 Thermostat switch
9Key switch
10 Glow signal
11 Glow plugs
12 Fuse
13 Fuse
14 Solenoid switch
15 A delayed fuse can be fitted if required
= Diode. Capacity: Current 3 amp. Reverse Voltage: 600V. (This is mandatory).
B
B
S
AC
17
30
50
19
N
F
1
2
3
4
9
10
11
5 7
6 8
12
13
15
14

Table of Contents

Related product manuals