Automatic shutdown connector
55 Amp alternator charge lamp
Note: Alternator charge lamp rating: 12V - 2.2W at 850 rev/min.
When the engine is at rest the alternator charge lamp is illuminated via the battery and it extinguishes when
the alternator operates.
The use of a lower wattage bulb than the above will increase speed at which self excitation occurs upon initial
run up, e.g. a charge lamp with a lower wattage bulb will have a rating of 12V - 1.2W at 1300 rev/min.
Pin number
connector
Wire colour Connection
1 Red Key switch - AC
2 Orange Key switch - 50
3 Red / Black Solenoid
4 Brown Oil pressure switch
5 Blue Coolant temperature switch
6 Black Ground (Earth)