86 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green
400 Series
Before fitting the atomiser, clean and dry the male and female threads of the atomiser and the cylinder head.
Apply a 2 mm (0.08 in) bead of sealant POWERPART universal jointing compound, part number 1861117, to
extend 6 mm (0.24 in) along the first two threads of the atomiser (3).