EasyManua.ls Logo

Perkins 854F-E34T - Indicator Lamp - Test

Perkins 854F-E34T
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(Table 71, contd)
Troubleshooting Test Steps Values Results
11. Use the Electronic Service Tool to Reset the IVS Threshold
Limits
The electronic service tool can be used to change the Idle Valida-
tion Min OFF Threshold and the Idle Validation Max ON Thresh-
old in order to suit the type of throttle that is installed. The limits
are shown in the Throttle Configuration screen which is located
in the Service menu.
A. Refer to Test Step 8 and record the raw value of the throttle sig-
nal when the idle validation switch changes from the CLOSED po-
sition to the OPEN position.
Note: The default value for the Idle Validation Min OFF Thresh-
old is 21%. The lowest value that should be set is 5%. The de-
fault value for the Idle Validation Max ON Threshold is 25%.
The maximum value that is expected is 28%.
B. Set the Idle Validation Min OFF Threshold to 3% below the
raw value that was previously recorded.
C. Set the Idle Validation Max ON Threshold to 3% above the
raw value.
D. Enter the new threshold limits into the electronic service tool.
Click Submit on the electronic service tool screen.
E. Turn the keyswitch to the OFF position and wait at least 5 sec-
onds. Turn the keyswitch to the ON position.
F. Repeat Test Step 8. Check that the IVS operates within the
newly set threshold limits.
Result: The fault is cleared after programming
the new calculated values.
Return the engine to service.
Result: The fault is not cleared.
Contact the Dealer Solution Network (DSN).
Complete the procedure in the order in which the
steps are listed.
If the procedure did not correct the issue, Contact the
Dealer Solution Network (DSN).
i06013882
Indicator Lamp - Test
Use this procedure under the following
circumstances:
The lamps are not receiving battery voltage.
The lamps are not operating correctly.
One of the following diagnostic codes is active:
Table 72
Diagnostic Trouble Codes for the Indicator Lamps
J1939
Code
Description Notes
623-5 Red Stop Lamp : Current Below Normal The Electronic Control Module (ECM) detects a low current condition in the
circuit for the shutdown lamp.
(continued)
144 UENR0612
Circuit Tests
This document has been printed from SPI2. NOT FOR RESALE