7. Download the flash file.
a. Connect the electronic service tool to the
diagnostic connector.
b. Select WinFlash from the Utilities menu
on the electronic service tool.
Note: If WinFlash will not communicate with the
ECM, refer to Troubleshooting, “Electronic Service
Tool Does Not Communicate”.
c. Select the engine ECM under the Detected
ECMs .
d. Press the Browse button in order to select
the part number of the flash file that will be
programmed into the ECM.
e. When the correct flash file is selected, press
the Open button.
f. Verify that the File Values match the
application. If the File Values do not match
the application, search for the correct flash file.
g. When the correct flash file is selected, press
the Begin Flash button.
h. The electronic service tool will indicate when
flash programming has been successfully
completed.
8. From the menu bar go to the following menu
options:
Service
Copy Configuration
ECM Replacement
9. Click on Load From File at the bottom of the
screen.
10. Select the correct ECM replacement file. Check
that the date and time stamp matches that of the
desired replacement file and click on OK .
11. Click on Program ECM at the bottom of the
screen.
12. Once the Programming Complete dialog box
appears on screen, click on OK .
13. Check for logged diagnostic codes.
i06022909
Electrical Connectors - Inspect
Most electrical faults are caused by poor connections.
The following procedure will assist in detecting faults
with connectors and with wiring. If a fault is found,
correct the condition and verify that the fault is
resolved.
Intermittent electrical faults are sometimes resolved
by disconnecting and reconnecting connectors. It is
very important to check for diagnostic codes
immediately before disconnecting a connector. Also
check for diagnostic codes after reconnecting the
connector. If the status of a diagnostic code is
changed due to disconnecting and reconnecting a
connector, there are several possible reasons. The
likely reasons are loose terminals, improperly
crimped terminals, moisture, corrosion, and
inadequate mating of a connection.
Follow these guidelines:
Never break the insulation of a wire in order to
access a circuit for measurements.
If a wire is cut, always install a new terminal for the
repair.
The connection of any electrical equipment and
the disconnection of any electrical equipment
may cause an explosion hazard which may result
in injury or death. Do not connect any electrical
equipment or disconnect any electrical equipment
in an explosive atmosphere.
Illustration 80 g01131019
Seal for a three-pin connector (typical example)
UENR0612 243
Service
This document has been printed from SPI2. NOT FOR RESALE