Inspections and Maintenance
102
BATTERIES
WARNING
Avoid sparks and open flames in the vicinity of batteries.
Battery acid is an aggressive fluid.
In the event of contact with the skin: rinse the skin profusely with
plenty of water.
Consult a doctor in the event of persistent redness or pain.
Remove polluted clothing and rinse in water.
In the event of contact with the eyes: rinse with plenty of water for
at least 15 minutes and consult a doctor.
If swallowed: do NOT induce vomiting. Rinse the mouth, drink two
glasses of water and consult a doctor.
In the event of inhalation: get fresh air, rest and consult a doctor.
- Check the electrolyte level; this should be approx. 10 mm above the plates or up
to the level indicator, if present. If necessary, top up the batteries with distilled
water.
- Check that the battery poles and terminals are clean and greased. If necessary,
coat the posts with an acid-free petroleum jelly.
D0 00 627-1