What to do if my Pfannenberg DTX 8161 Heat Pump shows a high temperature?
- LLawrence SanchezAug 12, 2025
If you are experiencing a high temperature fault with your Pfannenberg Heat Pump, you should check the heat load or check for other fault codes.
What to do if my Pfannenberg DTX 8161 Heat Pump shows a high temperature?
If you are experiencing a high temperature fault with your Pfannenberg Heat Pump, you should check the heat load or check for other fault codes.
What to do if there is a compressor fault in my Pfannenberg DTX 8161?
If your Pfannenberg Heat Pump is showing a compressor fault, you should check the compressor.
What to do if the external fan in my Pfannenberg Heat Pump is faulty?
In case of an external fan fault in your Pfannenberg Heat Pump, check the external fan and condenser, ensuring it is not dirty or blocked.
What to do if the condenser is dirty or blocked in my Pfannenberg DTX 8161 Heat Pump?
If the condenser of your Pfannenberg Heat Pump is dirty or blocked, check the condenser and the external fan.
What to do if my Pfannenberg Heat Pump has a power voltage fault?
If there is a power voltage fault with your Pfannenberg Heat Pump, check the power supply.
What to do if the evaporator is dirty or the airflow is blocked in my Pfannenberg DTX 8161?
If the evaporator is dirty or blocked, or if the internal airflow is blocked in your Pfannenberg Heat Pump, check the internal fan channel, evaporator, and internal fan.
Why does my Pfannenberg DTX 8161 exceed the temperature range?
Pfannenberg Heat Pump cooling units cannot operate in environments above 55 degrees.
What to do if the cabinet door is open on my Pfannenberg DTX 8161 Heat Pump?
If the cabinet door of your Pfannenberg Heat Pump is open, check the door switch.
Details on key components and the operational features of the cooling unit.
Comprehensive table of technical specifications, electrical data, and dimensions.
General guidelines and precautions for the correct installation of the cooling unit.
Step-by-step instructions for physically mounting the cooling unit.
Detailed instructions for connecting the unit's power supply and control wiring.
Details on key components and the operational features of the cooling unit.
Comprehensive table of technical specifications, electrical data, and dimensions.
General guidelines and precautions for the correct installation of the cooling unit.
Step-by-step instructions for physically mounting the cooling unit.
Detailed instructions for connecting the unit's power supply and control wiring.
| Protection category | IP 54 |
|---|---|
| Operating temperature range | -20 °C to +60 °C |
| Cooling Capacity | 800 W at 35°C |
| Heating Capacity | 400 W at -10°C |
| Ambient Temperature Range | -20 °C to +60 °C |