PG DRIVES TECHNOLOGY AC TRACTION – SIGMAGAUGE
Once the cut-out is ready, ensure that all debris is removed and the surface is clean.
Place the Sigmagauge in the hole.
Raise the Securing Bracket from beneath the dash surface and locate onto the mounting bolts.
Once located, fasten using the M5 nuts supplied.
To maintain a good weather seal, it is suggested that a waterproof adhesive is used to seal and
secure the Sigmagauge to the dash.
4 Configuring the Sigmagauge
To access the Gauge Set-up menu, press and hold the ‘SEL’ button for 3 seconds. Features such as the Service Interval Timer,
Hours Counter and Text Field can be adjusted and optionally protected with a pin code. Use the up and down arrow buttons to
choose an option, ‘SEL’ to select an option and the ‘+’ & ‘-’ buttons to amend the current value.
The table below shows the structure of the Gauge Set-up menu. It describes the action and range of each available parameter.
Ref. Parameter Sub Menu Reference Sub Menu Description Range & Action
1 Service timer 1. Svc interval Set the time interval for the
next service
0 – 32767 Hrs. (Warning starts
40 hours before service
required)
2. Count hours Set to count ‘work’ (drive) or
‘key’ hours
Work / Key Hrs.
3. Reset timer Resets the Service Timer
(sub menu ref ‘4’)
To confirm, press ‘SEL’
4. Svc time Indication of the actual
counter value
Indication only
2 Hours counter 1=Key, 2=Work Select to indicate ‘work’ or
‘key’ hours
Select with up & down arrows
and confirm with ‘SEL’
3 Information field 1. Adjust field Free 2x9 character field to
show customized text
4 Pincodes 1. Service timer Sets pin code for service
timer access
2. Information field Sets pin code for
information field access
Use up and down arrows for
position, ‘+’ & ‘-’ to change
value and ‘SEL’ to return to
menu
3. Reset all pincodes Reset all pin codes Contact PGDT
5 About SW version and date Indication of the software
version and date
Indication only
6 Return - Select to return to main
menu
Select with up & down arrows
and confirm with ‘SEL’
SK79646-01 89

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PG Drives Technology ACT445M SIGMADRIVE and is the answer not in the manual?

PG Drives Technology ACT445M SIGMADRIVE Specifications

General IconGeneral
BrandPG Drives Technology
ModelACT445M SIGMADRIVE
CategoryController
LanguageEnglish

Related product manuals