EasyManua.ls Logo

Philips 55PFL4909 - Power Supply CBA Top View

Philips 55PFL4909
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-19
IC1401
D
ILED3
VLED33
4
2
1
VLED4
ILED4
ILED2
VLED2
1
2
L1401
C654
C655
C1403
D653
D658
BC1402
C1417
C1418
C1419
D1401
CN501
R1415
GP002
D715
RESET
P-ON_H2
PROTECT3
PROTECT3
PROTECT3
BL-SW
BL-SW
BL-ADJ
BL-ADJ
CN1401
CN1201
J506
J500
J1404
J1410
J1408
J502
J507
J1402
J1403
J501
J1400
J504
J505
J1407
J503
J1405
J1401
J1409
CN1101
ILED1
VLED1
2
1
IC1301
TOP SIDE
COLD
C
BC1302
C1317
C1318
C1319
D1301
R1315
C651
C652
C657
D651
BC1202
D654
D655
C1217
C1218
L1301
D704
C1303
PROTECT3
BL-SW
BL-ADJ
BL-ADJ
J1406
J1302
J1307
J1202
J1203
J1310
J1210
J1301
J1305
J1304
J1209
J1213
J1309
J600
J1205
IC1101
IC1201
B
C1118
C1119
D1101
R1115
L1201
T1701
C1203
C1219
D1201
R1215
L1101
C1103
BC1102
C1117
J1104
J1300
J1105
J1308
J1109
J1306
J1700
J1303
J1102
HOT
COLD
IC1702
GP003
J750
21
A
GP001
C723
C724
C725
C730
D706
D710
D711
D712
D713
J1103
J1107
J1101
J1108
J701
J1106
J700
IC1601
LC12-55W-USA
BA4GR0F01021
3
C1706
C1708
C1711
BC1703
D1707
R1719
B-1704
C726
D714
C1602
BC1603
BC1604
C1614
C1622
45
54321
TOOL NO.
6
78
J1600
J1607
J1602
J1611
J1606
J702
J1609
J1612
J1608
J1604
UNDER SIDE
Q1704
C1709
C642
D601
D602
D603
D604
D607
C1612
C1615
C1621
C1623
C1626
D1603
D1605
R1624
T1601
T1602
C601
C605
D605
C1613
J1603
J704
J703
J1703
J1610
J1614
J1605
J1601
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
R618
C606
C616
C619
C620
C650
C665
D606
D609
D613
D619
D620
D650
B-601
Q601
BC602
BC603
L601A
C614
ALL+3.3V
POWER-GND
POWER-GND
POWER-GND
POWER-GND
POWER-GND
POWER-GND
AMP+13V
AMP+13V
AMP+13V
AMP+13V
POWER-GND
P-ON-21V
P-ON-21V
P-ON-21V
P-ON-21V
R602
C602
JS601
J601
J607
J603
J612
J602
J606
IC601
C656
D621
IC602
IC604
C692
D660
IC1602
C728
P-ON_H2
P-ON_H2
J609
J510
J512
J514
J511
J611
J605
J608
J513
J604
T601
CAUTION -
RISK OF FIRE -
REPLACE FUSE AS MARKED
LIVE
NEUTRAL
T 2.5A L/250V
1
2
3
4
5
6
7
R601
CN601
L602A
C604
F602
SA601
LED-CONT
PROTEC1
PROTEC3
RESET
BL-SW
P-ON-H2
BL-ADJ
CN501
J610
C640
C641
C643
BA4GR0F01021
Power Supply CBA Top View
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F602) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 2.5A, 250V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 2.5A, 250V.
2.5A 250V