8.2 Mechanical Data
8.2.1
Control and Power Supply Unit
Mounting : free standing on a table top or mounted
in a 19" rack (requires 3HU (Height
Units) with bracket set LBB 3311/00.
Information about how to make the
necessary brackets for table flush moun-
ting is included (page 21).
Dimensions (h x w x d) : 84 x 361 x 143 mm (with 5.5 mm feet);
3.4 x 14.2 x 5.6 in (with 0.22 in feet).
Weight : 1.5 kg (3.3 lb)
8.2.2 Delegate/Chairman Units
Dimensions (w x d x h)
- without mic. : 124 x 172 x 63 mm
(4.9 x 6.8 x 2.5 in)
- length of mic. from mounting
surface : /00 version : 313 mm (12.3 in)
/50 version : 488 mm (19.2 in)
- weigth : 0.9 kg (2.0 lb)
8.3 General Data
8.3.1
System Environmental Conditions
Temperature range
Storage and transport : -20 to +70°C (-4 to +158°F)
Operational : +5 to +45°C (+41 to 113°F)
Ambient humidity
Operational : 20% - 95% RH
Storage and transport : 0% - 99% RH
Air pressure : 600 mBar - 1100 mBar
Safety : acc. to EN 60065 and acc. to UL6500
(UL and cUL) for LBB 3310/00D)
Resistance to shock, vibration,
bump and transport : acc. to IEC68, 5G acceleration
EMC emission : acc. to EN 55103-1 and FCC rules
(part 15), class A
17