PIN 14 OF
CN1601
WF5
PIN 10 OF
CN1601
WF4
PIN 1 OF
CN1601
WF8
PIN 16 OF
CN1601
WF6
PIN 6 OF
IC1403
WF9
PIN 19 OF
CN1601
WF7
Main CBA Bottom View
BH97A0F01011A
1-12-25 1-12-26
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.