Instruction & Maintenance Manual Sheet 1.49
Phoenix ‘SPC10e’ Self Propelled Metering Chipping Spreader 03/12
1.2.6 Digital Meter Features
The digital meter, next to the front console, provides display of
the following parameters.
Ground speed in kilometres per hour km/h
Ground speed in miles per hour mph
Ground speed in metres per minute mpm
Two distance totalisers in metres. – M PART & M TOTAL
One can be used for site by site totals and one for
contract or weekly production totals.
These will record distanced travelled whenever the
machine is motion.
The r.p.m. of the centre FeedRoller. RPM
The ‘delay’ feature will allow for the start & stop of the
application of aggregate, to be a straight line across
the machines path. DELAY
To display each function use the ‘TOG’ button to move the
indicator across the display from left to right until it is above
the function to be displayed.
Distance Totaliser
For each distance travelled totals can be separately re-set to
‘zero’. To reset, scroll to M part or M total as required. Then
Press and hold RESET button.
At the same time press the ‘TOG’ button.
Release both buttons. The display will now show 0000 and
is ready to record a new total.
Carry out the same procedure to reset the other total
record.