PNOZ s3
Operating Manual PNOZ s3
21395-EN-10
11
Service life graph
The service life graphs indicate the number of cycles from which failures due to wear must
be expected. The wear is mainly caused by the electrical load; the mechanical load is negli-
gible.
Example
} Inductive load: 0,2 A
} Utilisation category: AC15
} Contact service life: 2,000,000 cycles
Provided the application requires fewer than 2,000,000 cycles, the PFH value (see techni-
cal details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With capacitive loads, any power surges that occur must be noted. With contac-
tors, use freewheel diodes for spark suppression.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ s3 Series and is the answer not in the manual?

Pilz PNOZ s3 Series Specifications

General IconGeneral
TypeSafety Relay
Supply Voltage24 V DC
Auxiliary Contacts1 N/C
Width22.5 mm
MountingDIN Rail
PLe
Category4
SILCL3
Rated Current6 A
Contact MaterialAgSnO2
Protection ClassIP20
Stop Category0
StandardsEN ISO 13849-1
Rated Voltage24 V DC
Operating Temperature-10 to 55 °C