1 SUB CONTRAST Sub Contrast adjustment (except for PC)
Adjustment required
2 SUB BRIGHT Sub Brightness adjustment (except for PC)
Adjustment required
3 SUB TINT Sub Tint setting (except for PC) 64
8 PULSE NUMBER Base pulse number adjustment (note) 8
9 ABL LEVEL ABL Level value adjustment (note) 128
BS5 ACL SW ACL setting ON
BS11 D RANGE SW Dynamic Range setting OFF
INITIALIZE mode (Common for all input signal types and formats)
SUB VIDEO
Adjustment Table or Parameter
Current Menu
Input Signal
INITIALIZE MODE 06–A/N
1 SUB VIDEO
Go to SUB VIDEO adjustment menu with "SET" key –––
2 MIRROR MODE Setting Mirror mode OFF
3 FULL MASK Setting Full mask display OFF
5 HOUR METER Displaying operation hour meter –––
6 BAUD RATE Setting Baud rate 4800
7 EEPROM INIT. Initializing EEPROM (Do not use) –––
8 MASK CONTROL Setting Original /4:3 displaying area motion mode. ON
9 DRIVE ADJ Go to DRIVE adjustment menu with "SET" key –––
BS5 FINAL SET UP Setting to default factory setting with "SET" key –––
(refer to Details of FINAL SETUP)
BS7 DISP POSI.
Go to
DISP POSI.
adjustment menu with "SET" key
–––
BS11 BRIGHT ENHANCE Setting Bright enhance
VIDEO: ON
(to enhance the luminance for the screen center) PC: OFF
OFF X
XY Y
OFF ON
1200 2400
19200
.......
OFF ON
SUB VIDEO mode (Common for all input signal types and formats)
SUB CONTRAST : 32
Adjustment Parameter
Setting Value
Current Menu
Input Signal
SUB VIDEO
MODE 06–A/N
OFF ON
OFF ON
Note ) If unnecessarily adjusted, power consumption of the unit is changed and the panel is
damaged. Adjust only in case of necessity.
Remote
Control Key
Adjustment
Parameter
Adjusting & Setting Item
Setting
Value
Remote
Control Key
Adjustment
Parameter
Adjusting & Setting Item
Setting Value
DRIVE ADJ mode (Common for all input signal types and formats)
X–SUS–B : 15
Adjustment Parameter
Setting Value
Current Menu
Input Signal
DRIVE ADJ MODE 06–A/N
Remote
Control Key
Adjustment
Parameter
Adjusting & Setting Item
Setting Value
1 X-SUS-B
Adjustment required
2 X-SUS-G 8
Sustain Drive Pulse adjustment
3 Y-SUS-B
Adjustment required
4 Y-SUS-G 8
10 R SIDE LEVEL 100
11 G SIDE LEVEL Side Mask color/level setting 97
12 B SIDE LEVEL 100
BS5 R FULL LEVEL 255
BS7 G FULL LEVEL Full Mask color/level setting 255
BS9 B FULL LEVEL 255