14
8.RecoveringBacktoDefaultConguration
IP address has been changed or admin password has been forgotten –
Note
Follow all the recovering back to default configuration steps as
shown in the example.
1.Power o the Industrial Managed PoE+ Switch and remove all the existing
connections.
2. Use the straight RJ45 cable to connect to port 1 and port 2 in the loop topology
as shown below:
3. Power on the Industrial Managed PoE+ Switch and 6 LNK/ACT LEDs will be lit.
4. Resetting Industrial Managed PoE+ Switch to the factory default is done when 6
LNK/ACT LEDs are lit again.
5. Remove the RJ45 cable from port 1 and port 2.
6.Reset the Industrial Managed PoE+ Switch to Factory Default conguration. The
Industrial Managed PoE+ Switch will then reboot and load the default settings as
shown below:
Default Username: admin
Default Password: admin
Default IP Address: 192.168.0.100
Default Subnet Mask: 255.255.255.0