Copyright Planika Sp. z o.o. www.planikafires.com 9
When the message
COOLING THE DEVICE
is displayed,
the fans that accelerate the cooling of the device switch
on.
COOLING
THE DEVICE
TEMP. TOO
HIGH
The acceptable device
operation temperature has
been exceeded.
Wait until the device cools down. The message will
change to
READY
.
When the message
COOLING THE DEVICE
is displayed,
the fans that accelerate the cooling of the device switch
on
COOLING
THE DEVICE
DEVICE HIT
The device has been hit
Wait until the device cools down. The message will
change to
READY
.
When the message
COOLING THE DEVICE
is displayed
the fans that accelerate the cooling of the device switch
on
COOLING
THE DEVICE
DEVICE
TILTED
The device has been tilted
Wait until the device cools down. The message will
change to
READY
.
When the message
COOLING THE DEVICE
is displayed
the fans that accelerate the cooling of the device switch
on
COOLING
THE DEVICE
CO2 LEVEL
TOO HIGH
The concentration of CO
2
has
been exceeded
Wait until CO
2
level in the room diminishes. It is advised
to open the windows or open the door to adjacent
rooms.
ERROR 1
There was a fuel spill or leak
detected.
Remove the funnel if it is placed in the filler, and then
turn off the device using the red button on the control
panel. If the spillage is excessive the source of power
needs to be disconnected. Dry the visible moisture.
Leave the device switched off for at least 1h. If the
message is still displayed after restart, turn off the device
for a longer time. If this does not solve the problem call
SERVICE.
ERROR 2
An error of the heater
temperature sensor.
Turn off the device using the red button on the control
panel. Turn it on after a while. If the message does not
disappear call SERVICE.
ERROR 3
An error of the furnace
temperature sensor.
ERROR 4
An error of the reservoir
temperature sensor.
ERROR 5
Movement sensor actuated.
If the device was moved during
operation
.
The message
will disappear with the disappearance of the source of
movement.
ERROR 6
An error of the fuel level
probe.
Turn off the device using the red button on the control
panel. Turn it on after a while. If the message does not
disappear call SERVICE.
ERROR 10
The heater is damaged.
Turn off the device using the red button on the control
panel. Turn it on after a while. If the message does not
disappear call SERVICE.
ERROR 14
Limiting switch K2 Call SERVICE.
ERROR 15
The device is tilted (set on a
non-levelled surface).
Switch off the device using the red button on the control
panel. Level the surface on which the device stands and
restart the device.