Copyright Planika Sp. z o.o. www.planikafires.com 10
ERROR 16
the heater sensor.
Turn off the device using the red button on the control
panel. Turn it on after a while. If the message does not
disappear call SERVICE.
ERROR 17
Exceeded time of waiting for
the appearance of flame.
ERROR 20
Too low temperature in the
hearth while turning on.
the device.
ERROR 21
Too low temperature in the
hearth during operation.
Turn off the device with the red button and wait until it
cools down. Try to restart the device.
ERROR 31
Fuel spilled within fuel pump
Turn off the device with the red button and wait at least
1h. Try to restart the device. If the message does not
disappear wait longer until the moisture evaporates
completely. If the message does not disappear call
SERVICE.
ERROR 98
remote control programming
Try to program the remote control again.
ERROR 99
No connection between the
control panel and
microprocessor
Try to restart the device.. If the message does not
disappear call SERVICE.
III. Customer’s menu
If READY or NO FUEL message is visible on the display, you may access Customer’s menu. To do this,
hold ‘+’ button for 8s and menu will appear on the display.
It is possible to operate the menu only by means of the buttons on the control panel. To move between
the categories use ‘+’ and to choose a particular category use ‘-‘. Leaving the menu unused for 5s will
result in coming back to the main display.
1) Lock the device
This function allows to lock the device in order to avoid being manipulated by unauthorized persons.
To turn this function on press ‘-‘ on the control panel. This screen appears: