Planmeca Compact
i Classic
Quick guide
Patient chair control
Control panel
Chair to autoposition A
Short activation
Backrest down
Long activation
Chair to autoposition B
Short activation
Backrest up
Long activation
Chair to autoposition C
Short activation
Chair up
Long activation
Chair to autoposition D
Short activation
Chair down
Long activation
Chair to rinsing position
Short activation
when LED OFF
Chair to previous position
Short activation
when LED ON
Chair to rinsing position only
Long activation
Flexy button
Chair to rinsing position
Foot control
C
A
D
B
Short activation
Short activation
Short activation
Long activation
Long activation
Long activation
Short activation
Chair to autoposition A
Long activation
Backrest down
Chair to autoposition B
Backrest up
Chair to autoposition C
Chair up
Chair to autoposition D
Chair down
Chair to rinsing
position
Chair to rinsing
position
Question and Answer IconNeed help?

Do you have a question about the Planmeca Compact i Classic and is the answer not in the manual?

Summary

Patient Chair Control

Control Panel Operations

Controls for chair movement, backrest, and autopositions via the main panel.

Flexy Button Functionality

Single button control for chair rinsing position on the Flexy button.

Foot Control for Chair

Pedal controls for chair movement, autopositions, and backrest adjustments.

Dental Unit Control

Dental Unit Control Panel

Panel controls for bowl rinse, cup fill, and operating light functions.

Dental Unit Foot Control

Pedal controls for dental unit functions including call functions and rinse.

Instrument Control

Instrument Control Panel

Panel controls for unit-controlled instruments like micromotor, scaler, and turbine.

Instrument Foot Controls

Pedal controls for instrument activation, scaler functions, and camera/scanner.

Programming Settings

Patient Chair Autoposition Programming

Procedure for setting and accepting new patient chair positions.

Unit Settings Programming

Programming unit functions and adjusting values for various settings.

Planmeca Solanna Light Settings

Settings for operating light intensity and white light tone.

Instrument Settings Programming

Programming instrument functions like spray, chip blow, and polymerization cycle.

Overview

This document provides a quick guide for the Planmeca Compact™ i Classic dental unit, detailing its patient chair, dental unit, and instrument controls, as well as programming functionalities.

Patient Chair Control

The patient chair control panel and foot control allow for precise positioning of the patient chair.

Control Panel Features:

  • Chair to autoposition A, B, C, D: Short activation moves the chair to a pre-programmed position.
  • Backrest down/up: Long activation adjusts the backrest.
  • Chair up/down: Long activation moves the entire chair up or down.
  • Chair to rinsing position: Short activation moves the chair to a rinsing position when the LED is OFF.
  • Chair to previous position: Short activation returns the chair to the previous position when the LED is ON.
  • Chair to rinsing position only: Long activation moves the chair to the rinsing position without returning to the previous position.

Flexy Button:

  • Chair to rinsing position: A dedicated button for moving the chair to the rinsing position.

Foot Control Features:

The foot control mirrors many of the panel functions for hands-free operation.

  • Chair to autoposition A, B, C, D: Short activation.
  • Backrest down/up: Long activation.
  • Chair to rinsing position: Dedicated button.

Programming Patient Chair Autoposition Settings:

  1. Move chair to required position: Manually adjust the chair to the desired position.
  2. Switch operating light On/Off: Toggle the operating light.
  3. Start programming: Initiate the programming sequence.
  4. Press desired button: Select the A, B, C, or D button on the control panel to store the chair position.
  5. Accept new autoposition: Confirm the new setting.

Dental Unit Control

The dental unit control panel and foot control manage various functions related to the dental unit's operation.

Control Panel Features:

  • Bowl rinse: Short activation.
  • Cup fill and bowl rinse: 2x short activation or 0.5-1 sec. activation.
  • Cup fill as long as pressed: Long activation.
  • Door open / assistant call function for preprogrammed time: Short activation.
  • Door open / assistant call function as long as pressed: Long activation.
  • Operating light On ▶ Off: Short activation toggles the light.
  • Intensity of operating light: Long activation adjusts the intensity.
  • Maintenance procedure:
    • Short flushing: 3 sec. activation.
    • Long flushing: 6 sec. activation.

Foot Control Features:

The foot control provides access to preprogrammed unit functions, including:

  • Door open / assistant call function for preprogrammed time: Short activation.
  • Door open / assistant call function as long as pressed: Long activation.
  • Bowl rinse: Short activation.
  • Cup fill and bowl rinse: 2x short activation or 0.5-1 sec. activation.
  • Cup fill as long as pressed: Long activation.

Programming Unit Settings:

  1. Start programming: Initiate the programming sequence.
  2. Select function*: Choose from available unit functions:
    • Duration of cup filling: 2 - 10 sec.
    • Duration of bowl rinsing: 5 - 240 sec.
    • Duration of door open/assistant call signal: 0 - 250 sec.
  3. Adjust value: Modify the selected function's parameter.
  4. Accept new value: Confirm the new setting.

Programming Planmeca Solanna Operating Light Settings:

  1. Start programming: Initiate the programming sequence.
  2. Select operating light: Choose the operating light.
  3. Adjust/select value**: Modify the operating light's parameters:
    • Intensity: 30 - 100%.
    • White light tone: Warm > Neutral > Cool.
    • Maximum brightness: Mild > Strong > Glaring.
  4. Accept new value: Confirm the new setting.

Instrument Control

The control panel and foot control manage various dental instruments.

Control Panel Features (Unit controlled instrument activated):

  • Micromotor or turbine:
    • Automatic chip blow On ▶ Off: Toggles automatic chip blow.
    • Water & air / Air / No spray: Selects spray type.
    • Scaler Spray On ▶ Off: Toggles scaler spray.
  • Scaler:
    • Change operation mode: Cycles through operation modes.
  • Micromotor:
    • Reverse rotation On ▶ Off: Toggles reverse rotation.
  • Turbine:
    • Quickstart On ▶ Off: Toggles quick start.
  • Micromotor Bien-Air MCX:
    • RPM limit On ▶ Off: 2 sec. activation to toggle RPM limit.
    • Torque limit 25% ▶ 50% ▶ 75% ▶ 100% (= torque limit disabled): 4 sec. activation to cycle through torque limits.

Foot Control Features (Unit controlled instrument activated):

  • Micromotor or turbine (standard pedal):
    • Drive instrument: Activates the instrument.
    • Momentary spray*: Activates spray temporarily.
    • Water & air / Air / No spray: Short activation to select spray type.
    • Manual chip blow: Long activation.
  • Scaler (standard pedal):
    • Drive scaler: Activates the scaler.
    • Momentary spray*: Activates spray temporarily.
    • Spray On ▶ Off: Short activation to toggle spray.
  • Micromotor, turbine or scaler:
    • Preprogrammed instrument function**: Activates a pre-programmed function.
  • Polymerisation light:
    • Start ▶ Stop: Activates/deactivates the light.

Intraoral Camera:

  • Activate/deactivate intraoral camera (default): Toggles the camera.
  • Freeze / Unfreeze: Freezes or unfreezes the image.
  • Save still picture: Short activation saves the current image.

Planmeca Intraoral Scanner:

  • Activate/deactivate instrument view*: Toggles the instrument view.
  • Generate model: Initiates model generation.
  • Select scanning mode: Cycles through scanning modes.
  • Start scanning: Short activation begins scanning.
  • Take image: Long activation captures an image.

Programming Instrument Settings:

  1. Activate instrument: Select the desired instrument.
  2. Start programming: Initiate the programming sequence.
  3. Select function***: Choose from available instrument functions:
    • Spray water: 0 (off) - F=100 (full).
    • Spray air: 0 (off) - F=100 (full).
    • Chip blow water: 0 (off) - F=100 (full).
    • Chip blow air: 0 (off) - F=100 (full).
    • Intensity of instrument light: L. OFF (off), 70 - 100%.
    • Duration of polymerisation cycle: 5 - 100 sec.
  4. Adjust value: Modify the selected function's parameter.
  5. Accept new value: Confirm the new setting.

*If enabled by service technician. **Can be changed by service technician.

For detailed instructions, refer to the user's manual.

Planmeca Compact i Classic Specifications

General IconGeneral
BrandPlanmeca
ModelCompact i Classic
CategoryDental equipment
LanguageEnglish