Tube Voltage | 60-70 kV |
---|---|
Tube Current | 7 mA |
Type | Dental Unit |
Power Supply | 230 V, 50/60 Hz |
Control System | Touch screen |
Integrated systems | integrated suction system |
Exposure Time Range | 0.01 – 3.2 s |
Important warnings and precautions for safe operation of the dental unit.
Description of safety switches and their functions that stop chair movements.
Methods to quickly stop the dental unit's chair movements.
Overview of different dental unit configurations and their components.
Details of components that can be detached from the dental unit.
Identification of dental unit parts that come into contact with the patient.
Information about the cuspidor bowl, its positioning, and cleaning.
Details on how to move and handle the monitor.
Instructions for locking, adjusting height, and moving the mobile cart.
Instructions for attaching a tablet to the tablet holder.
Information on USB ports for connecting intraoral cameras and memory sticks.
Details on water and air quick-connectors for external devices.
Information on the multiple socket outlet for medical devices.
Details on connecting the dental unit to Planmeca Romexis software.
Information on mounting and positioning the Planmeca ProX X-ray unit.
Instructions for connecting and using the Planmeca intraoral scanner.
Overview of operation and features of the Planmeca Solanna operating lights.
Description of Over-the-Patient (OP) and Side delivery arms.
Details on instrument consoles with balanced and hanging-tube instruments.
Information on connecting and disconnecting quick-connector hoses.
Overview of programmable functions for instruments like spray, chip blow, and light.
Description of different types of tray tables available for the unit.
Introduction and setup instructions for the sterile water system.
Description of adjustable and chair-mounted suction arms.
Details about the Flexy-holder for suction handpieces and supplementary holders.
Step-by-step guide for removing and replacing suction tubes.
Explanation of the patient recognition sensor and its icons.
Instructions for operating the automatic legrest and its locking mechanism.
Procedure for positioning the patient chair in Trendelenburg position.
Information on moving, locking, and removing armrests.
Instructions for adjusting the height, angle, and position of the manual headrest.
Overview of operating the motorised headrest via foot control or joystick.
Identification and function of buttons on the instrument console control panel.
Using the control panel as a touchpad and computer mouse/keyboard.
Description of the control panel functions on the Flexy-holder.
Overview of the integrated foot control and its versions.
Differences between standard and wide foot control pedals.
Detailed functions of center, side knobs, and pedals.
Information on the optional wireless foot control, battery, and charging.
Methods for signing into the dental unit using PlanID or user name.
Procedure for signing out of the dental unit.
Overview of personal settings and their storage.
Steps to create a new user profile on the dental unit.
Procedure for deleting a user profile from the dental unit.
How to edit user settings like name, language, and color theme.
Instructions for resetting personal settings to factory defaults.
Prerequisites for assigning a PlanID card to a user.
Step-by-step guide to assign a PlanID card to a user from the dental unit.
Accessing and understanding the 'About this unit' information window.
Information about the dental unit model.
Display of the dental unit's serial number.
Display of the dental unit's software version.
Accessing service-related information and tools.
Viewing and understanding network settings for Romexis and Solanna Vision.
Viewing help and error messages logged by the unit.
Enabling or disabling the Bluetooth connection.
Displaying software licences used by the dental unit.
Instructions for manually operating the patient chair and backrest movements.
Overview of automatic chair positions and their storage.
How automatic chair positions are stored and selected.
Selecting the display format for automatic chair positions.
Steps to select automatic chair positions via control panel or foot control.
How to select the rinsing position and return to working position.
Methods to quickly stop chair movements.
Operating the motorised headrest in normal mode using joystick or foot control.
Operating the motorised headrest in tilt mode using joystick or foot control.
Instructions for changing the dental unit's language.
Procedures for rinsing the bowl using the control panel or foot control.
Instructions for filling the cup and rinsing the bowl.
Activating and managing preprogrammed timer settings.
Activating door opening or assistant call functions.
Overview of operation and features of the Planmeca Solanna operating lights.
Prerequisites and activation of the Solanna Vision camera.
Using the control panel display as an X-ray film viewer.
Principles of active instrument operation and exchange.
Functions and operation of the micromotor.
Additional features of the Bien-Air MCX micromotor.
Additional features of the Bien-Air MX2 micromotor.
Additional features of the Morita TORX micromotor.
Using the Morita Apex locator for root canal measurements.
Overview of turbine operation and features.
Overview of scaler operation and safety precautions.
Instructions for using the Lumion Plus polymerisation light.
Connecting and operating the intraoral camera with Planmeca Romexis.
Using the Planmeca intraoral scanner with software and foot control.
Operation of saliva and high-volume suction handpieces.
How to operate the tilting high-volume suction handpiece.
Overview of programming personal settings for chair, light, and instruments.
Customizing the main window's swipe menu by organizing items.
Saving and selecting automatic chair positions.
Adjusting settings for instruments like speed, spray, and light.
Programming up to six timer settings.
Adjusting flow rates and durations for bowl rinse and cup fill.
Adjusting intensity, color temperature, and gesture sensor settings.
Adjusting the time for door open or assistant call functions.
Setting and calibrating the dental unit's clock.
Setting the date and selecting the date format.
Adjusting disinfectant concentration and flushing durations.
Confirming the suction disinfectant container fill to reset the counter.
Pairing and configuring wireless foot control settings.
Procedure for calibrating the dental unit's clock.
Identification of cuspidor parts requiring maintenance and cleaning.
Recommended intervals for running flushing and cleaning programs.
Important notes and precautions before starting cleaning procedures.
Detailed steps for performing short instrument flushing.
Detailed steps for performing long instrument flushing.
Procedure for cleaning the suction system and tubes.
Procedures for weekly waterline cleaning.
Overview of approved disinfectants and cleaning guidelines.
Table detailing cleaning methods for various dental unit surfaces.
Guidelines for cleaning and servicing dental instruments.
Cleaning procedures for the instrument console and oil collector.
Cleaning and maintenance of cuspidor parts.
Daily, weekly, and after-working-day cleaning procedures for the suction system.
Cleaning and maintenance for the ActiveAqua water treatment system.
Information on using the WEK water disinfection system.
Information on cleaning the Planmeca ProX X-ray unit.
Information on cleaning the Planmeca ProSensor sensor.
Information on cleaning the Planmeca intraoral scanner.
Guidelines for cleaning the external PC, mouse, and keyboard.
Overview of the Planmeca ActiveAqua water treatment system.
Weekly measurement of free chlorine levels in the outgoing water.
Procedure for changing the ActiveAqua prefilter when prompted.
Confirming prefilter changes to reset the counter.
Adjusting water hardness and electrolysis strength in ActiveAqua settings.
Overview of the Clean Water System (CWS) and its purpose.
Weekly cleaning of waterlines with disinfectant.
Types of safety messages: notifications, help messages, and error messages.
List of help messages with their meanings and actions.
List of error messages categorized by system.
List of consumable suction handpieces with order numbers and materials.
Details of sterile water hoses, including order number and material.
List of consumable infection control parts with order numbers.
List of disinfectants used for cleaning and maintenance.
Guidelines for safe disposal of dental unit parts and hazardous waste.
Detailed technical specifications of the dental unit.
Electrical classification types for various instruments.
Information on positioning and patient area dimensions.
Example of optimal positioning of dentist and assistant during treatment.
Defining the patient area and safety guidelines within it.
Dimensional drawings for OP delivery with balanced instrument arms.
Dimensional drawings for OP delivery with hanging-tube instruments.
Dimensional drawings for side delivery with hanging-tube instruments.
Dimensions and specifications of the dental unit cart.
Water consumption rates for various unit components.
Declaration of conformity for radio equipment type PlanID™.
EU Declaration of Conformity for the PlanID RFID-reader.
FCC compliance notice for the wireless foot control.
FCC compliance notice for the PlanID RFID-reader.
Industry Canada compliance statement for radio equipment.
Industrie Canada declaration of conformity for radio equipment.
Information on FCC RF exposure limits for the PlanID device.